| Refrigeration and Heating System |
| Compressor |
1/3
HP Copeland hermetic |
| Condenser |
Air
Cooled |
| Heat of Rejection |
3,000 BTUH (maximum rated chamber load at maximum cooling rate from high temperature soak) |
| Heater
Power |
500
Watts |
| |
| Instrumentation |
| Temperature
Controller |
256 steps, 10 profiles, ramp and soak programmable memory. RS-232C
interface. Watlow Series F4.
More details >> |
| Limit
Controller |
Independent of temperature controller. User adjustable high and low
temperature limits. Shuts down the chamber if limits are exceeded.
Watlow Series SD. |
| |
| Power
Requirements |
| Input
Voltage |
Standard
Model 107
120 V nominal (110 to 126 VAC), 60 Hz, 1 PH
Max Current Draw 10 A, Recommended Minimum Service 15 A
Export Model
107-EX
230 V nominal (209 to 253 VAC), 50 Hz, 1 PH
Max Current Draw 5 A, Recommended Minimum Service 10 A |
| |
|
| Physical
Characteristics |
| Inside
Dimensions |
12"
W x 9" H x 11.25 " D, 0.7 cubic feet
(305 x 229 x 288 mm, 20 liters) |
Outside
Dimensions
(nominal) |
16.5"
W x 26" H x 25.25" D
(419 x 660 x 641 mm)
Door latch adds 2" to width. |
| Minimum
Installed Clearance |
12"
from the rear |
| Access
Ports |
3" ports (2.83" inside
diameter) on left and right side (two total). Supplied with silicone
foam port plugs |
| Weight |
Chamber
Weight: 124 pounds (56 kg)
Shipping Weight: 158 pounds (71 kg) |
| Sound
Level |
52
dBA in cooling mode (A-weighted, measured 36" from the front
surface, 63" from the floor, in a free-standing environment) |