| TestEquity Model 1027C Temperature Chamber |
| Specifications Download the Manual Prices | |
|
|
| The
Features You Want - Included at No Extra Charge...
High/Low Temperature
Limit Controller and Alarm Viewing Window Two 4" Access
Ports Adjustable Shelf Chamber Condensate
Drain Casters Built-In Refrigeration
Gauges
|
|
| TECHNICAL
FEATURES
No-Sweat Cabinet The window is constructed of 6 panes of tempered glass separated by low-conductivity spacers to keep thermal losses to a minimum. Our unique design virtually eliminates exterior window sweating during normal temperature cycling conditions. The stainless-steel interior liner is heliarc welded, while the refrigeration compartment behind the liner is double-insulated and carefully sealed. These design features reduce thermal losses and prevent moisture migration, ensuring years of optimum performance while keeping the cabinet rust-free. Reliability & Safety
Thats Designed In All electrical control components are UL approved. Each branch circuit is individually fused. A main power disconnect switch is provided on the front panel. The nichrome air-heater has a low watt-density and even heat distribution for reliable performance and fast response. A fusible link provides fail-safe protection against thermal runaways, in addition to the microprocessor-based high/low limit controller. The side and rear panels are removable to permit complete access to the refrigeration system for ease of service and preventive maintenance. About
Copeland Glacier™ Compliant Scroll® Compressors |
|
| Should
I buy a TestEquity 1027S Single-Stage or 1027C
Cascade Chamber?
TestEquity Single-stage refrigeration systems are capable of achieving workspace temperatures down to -35°C. This is fine for many commercial and industrial tests that require low temperatures of typically 0°C, -10°C or -25°C. A single-stage system uses one compressor to directly cool the workspace. Single-stage systems offer these benefits over similarly-sized cascade systems:
TestEquity Cascade refrigeration
systems are capable of achieving workspace temperatures down to -75°C.
This is required for many ruggedized industrial, automotive and military
tests that require low temperatures of typically -40°C, -55°C
or -65°C. A cascade system uses two interdependent compressors.
One compressor (low-stage) directly cools the workspace. The other
compressor (high-stage) cools a heat-exchanger (cascade condenser)
to remove heat from the low-stage. If you need to go below -35°C,
choose the TestEquity 1027C. |