   TestEquity Model 1007S Temperature Chamber - Detailed Specifications

<< Back to Product Page  PDF Data Sheet

Temperature Range -35°C to +175°C
Control Tolerance ±0.5°C (Measured at the control sensor after stabilization)
Uniformity ±0.5°C (Variations throughout the chamber after stabilization)

Cool Down Transition Time (empty)*

Start Temp

End Temp

+23°C 0°C -10°C -20°C -30°C -35°C
+23°C ---- 1.5 min 3.5 min 7 min 13 min Ultimate
+85°C 5 min 10 min 14 min 18 min 26 min Ultimate
+150°C 12 min 19 min 22 min 26 min 33 min Ultimate
 

Cool Down Transition Time (with 25 lb. aluminum load)*

Start Temp

End Temp

+23°C 0°C -10°C -20°C -30°C -35°C
+85°C 10 18 min 22 min 29 min 41 min Ultimate
+150°C 21 33 min 38 min 43 min 56 min Ultimate
 

Heat Up Transition Time (empty)*

Start Temp

End Temp

+23°C +50°C +85°C +125°C +150°C +175°C
+23°C ----- 1.5 min 7 min 14 min 20 min Ultimate
0°C 1.5 min 3.5 min 13 min 20 min 23 min Ultimate
-10°C 2.2 min 4.2 min 14 min 22 min 25 min Ultimate
-35°C 5.5 min 10 min 16 min 23 min 29 min Ultimate


Rate Of Change

To calculate rate of change for a particular condition, take the difference between the Start Temp and End Temp and divide by the Transition Time.
Cool Down Example (empty): From +85°C to -10°C = 95°C / 14 min = 6.8°C/min.
Cool Down Example (with 25 lb. load): From +85°C to -10°C = 95°C / 22 min = 4.3°C/min.
Heat Up Example: From -35°C to +85°C = 120°C / 16 min = 7.5°C/min.

*Note: Transition times are measured after a 2 hour soak at the respective start temperature.


Live Load Capacity
+23°C 0°C -10°C -20°C -30°C
1,400 Watts 1,000 Watts 850 Watts 625 Watts 300 Watts

Refrigeration and Heating System

Refrigerant R-404A (Dupont HP62)
Compressors 1 HP Copeland hermetic
Condenser Air Cooled
Heater Power 2,000 Watts
 

Instrumentation

Temperature Controller

256 step, 40 profile, ramp and soak programmable memory. RS-232 interface.
More details >>

Limit Controller Independent high and low temperature limits. Triggers an audible alarm and shuts down the chamber. Relay contacts provide a safety power interlock for test sample.
Chart Recorder   (Optional) Honeywell DR4300 Series. One pen, 10" circular chart. Mounts in lower front door.

Input Power Requirements
230 V ±10%, 60 Hz, 1 PH Max Current Draw 22 A; Recommended Service 30 A
208 V -5/+10%, 60 Hz, 1 PH Max Current Draw 22 A; Recommended Service 30 A

Input may be configured for 230 V or 208 V in the field by changing jumpers. Single phase input only. Call for other voltages or 50 Hz operation.

Customer power source must be hard-wired to the chamber by a qualified electrician. Power cord and plug is not included.

 

Physical Characteristics

Inside Dimensions

24" W x 21" H x 24" D (7 cubic feet)

Outside Dimensions* 33" W x 68.75" H x 54.25" D (nominal)
*Door latch adds 3" to width on right side (may be removed to permit move-in through a 36" doorway). Circulator motor and housing adds 6" to height.
Minimum Installed Clearance 18" from the left and right side
24" from the rear
Window Viewing Area 13.5" W x 11.5" H
Access Ports 4" Port on left and right side (two total)
Supplied with foam plugs
Weight Chamber Weight: 785 pounds
Shipping Weight: 910 pounds
Sound Level 62 dBA in cooling mode (A-weighted, measured 36" from the front or side surface, 63" from the floor, in a free-standing environment)

NOTE: Performance is typical and based on operation at 23°C (73°F) ambient and nominal input voltage. Designed for use in a normal conditioned laboratory. Operation at higher ambient temperatures may result in decreased cooling performance. Additional ports and shelves will also affect performance. Operation above 30°C (85°F) or below 16°C (60°F) ambient is not recommended.